Trgovina
-
Technical data Sunny Island 6.0H Sunny Island 8.0H AC output (loads / stand-alone grid) Rated grid voltage / AC voltage range 230 V / 202 V … 253 V 230 V / 202 V … 253 V Rated frequency / frequency range (adjustable) 50 Hz / 45 Hz … 65 Hz 50 Hz / 45 Hz … 65 Hz Rated power (for Unom / fnom / 25 °C / cos ϕ = 1) 4600 W 6 000 W AC power at 25 °C for 30 min / 5 min / 3 sec 6 000 W / 6 800 W / 11 000 W 8 000 W / 9 100 W / 11 000 W AC power at 45 °C 3 700 W 5 430 W Rated current / maximum output current (peak) 20 A / 120 A 26 A / 120 A THD output voltage / power factor with rated power < 4 % / -1 … +1 < 4 % / -1 … +1 AC input (PV array grid or MC box) Rated input voltage / AC input voltage range 230 V / 172.5 V … 264.5 V 230 V / 172.5 V … 264.5 V Rated input frequency / allowable input frequency range 50 Hz / 40 Hz … 70 Hz 50 Hz / 40 Hz … 70 Hz Maximum AC input current 50 A 50 A Maximum AC input power 11 500 W 11 500 W Battery DC input Rated input voltage / DC voltage range 48 V / 41 V … 63 V 48 V / 41 V … 63 V Maximum battery charging current 110 A 140 A Rated DC charging current / DC discharging current 90 A / 103 A 115 A / 136 A Battery type / battery capacity (range) FLA VRLA / 100 Ah … 10 000 Ah FLA VRLA / 100 Ah … 10 000 Ah Charge control IUoU charge procedure with automatic full charge and equalization charge IUoU charge procedure with automatic full charge and equalization charge Efficiency / self-consumption Maximum efficiency 96 % 96 % Self-consumption without load / standby < 26 W / < 4 W < 26 W / < 4 W Protective devices (equipment) AC short-circuit / AC overload ● / ● ● / ● DC reverse polarity protection / DC fuse – / – – / – Overtemperature / battery deep discharge ● / ● ● / ● Overvoltage category as per IEC 60664-1 III III General data Dimensions (width x height x depth) 467 mm x 612 mm x 242 mm 467 mm x 612 mm x 242 mm Priority 63 kg 63 kg Operating temperature range -25 °C … +60 °C -25 °C … +60 °C Protection class according to IEC 62103 I I Climatic category according to IEC 60721 3K6 3K6 Degree of protection according to IEC 60529 IP54 IP54 Features / function Operation and display / multifunction relay External via SRC-20 / 2 External via SRC-20 / 2 Three-phase systems / parallel connection ● / ● ● / ● Integrated bypass / multicluster operation – / ● – / ● State of charge calculation / full charge / equalization charge ● / ● / ● ● / ● / ● Integrated soft start / generator support ● / ● ● / ● Battery temperature sensor / data cables ● / ● ● / ● Certificates and approvals http://www.sma.de/en http://www.sma.de/en Warranty: 5 years ● ● Accessory Battery cable / battery fuse ○ / ○ ○ / ○ Interface SI-COMSMA (RS485) / SI-SYSCAN (Multicluster ○ / ○ ○ / ○ Extended generator start “GenMan” ○ ○ Load-shedding contactor / battery current measurement ○ / ○ ○ / ○ Type designation SI6.0H-11 SI8.0H-11 ● Standard features
○ Optional features
— Not available
Data at nominal conditions